Temperature ControlleriB6 / iB12
5.6.2 Alarm Parameters and Settings
Name Applies to Range/
Choices
Default Description & Interactions
Selected Zones
All Zones
Closed Loop Control
Open Loop Control
Inhibit
Seconds
0 to 999
seconds
0 (off) Number of seconds the controller
should wait after zone is taken
out of Idle before signaling a low
alarm
High Dev
Setpoint
1 to 537 °C
1 to 999 °F
17 °C
30 °F
Number of degrees the process
value must exceed the setpoint to
trigger the alarm state
Low Dev
Setpoint
1 to 537 °C
1 to 999 °F
17 °C
30 °F
Number of degrees the process
value must fall below the setpoint
to trigger the alarm state
Alarm Silence
Seconds
  
0 to 600
seconds
120 seconds Number of seconds the audible
alarm on the controller will be
silenced when
is pressed.
5.7 Supervisor Parameters
5.7.1 Introduction
You can use the Superv [Supervisor] Config menu to specify the values of several parameters related
to process protection for the selected zones. You can also use this menu to set up parameters that
apply to the whole controller.
The Superv Config menu can be password protected. iB6 and iB12 Temperature Controllers are
shipped with the Supervisor password set to 100, which disables this feature. You can use this menu
to specify a different password. Only users who know your new three-digit password will be able to
view and change parameters in the Superv Config menu.